Design and program protective relays and controls, RTUs, substation logic processors, and associated systems.
Analyze Protection System operations and assist in timely return to service.
Conduct, analyze and process power system studies (e.g., load flow, short-circuit, grounding, etc.).
Oversee quality and accuracy of numerous electrical engineering consultants and electrical contractors associated with new project development and operational substations.
Perform Root Cause Analysis and corrective action for protection systems operations and BOP equipment failure.
Develop technical specifications and scopes of work for maintenance, testing, repairs, and upgrades to BOP facilities.
Assist in development and upkeep of design standards, procedures, and documentation.
Provide technical assistance to internal and external stakeholders for a wide variety of projects involving BOP facilities.
In the event of critical failures, provide support to site personnel with analyzing failures and support switching procedures outside of working hours (on a rotation basis with other team members).
Assist in the development and upkeep of NERC PRC compliance.
Streamline processes, documentation, and evidence to improve scalability, program management, and automation.
Must be willing to work in high and medium voltage substation and collector system facilities.
On-site work may involve inclement weather, electrical hazards, climbing turbines and ladders, and occasionally lifting up to 50 pounds.
Provide clear direction for numerous contractors performing on-site implementation work.
Effectively provide training and mentoring for junior-level engineering personnel
Qualifications
B.S. in Electrical Engineering, Computer Engineering/Science or equivalent degree required
Four or more years of direct experience required. Experience to include designing power systems including protection and controls, RTUs and integration, substations, and/or OH/UG facilities.
Working knowledge of Industry and Regulatory Standards (IEEE, NEC, NESC, NETA, OSHA, etc.)
Working knowledge of NERC PRC Standards
Solid and demonstrated understanding of elementary diagrams, SEL and/or GE relay settings development, and protective device coordination
Working knowledge of AutoCAD and the development of electrical design drawings
A current driver’s license is required
Protective relay commissioning and testing experience
Working knowledge of IEC 61131-3 programming, or the fundamentals of procedural and structural programming, as well as digital logic
Working knowledge of industrial communication protocols (DNP3, Modbus, SEL, Mirrored Bits, etc.), and serial/Ethernet network topology (OSI layers 1-4)
Working knowledge of power system modeling software (such as EasyPower or ETAP), Aspen Relay Database, SEL AcSELerator, Mathcad Prime, and AutoCAD
Demonstrated, hands-on testing experience with relays and RTUs
Fluent in written and spoken English
Competencies
Develop Self & Others
Empower to grow
Collaborate and Share
Be a role model
Focus to achieve results
Be agile
Technical Skills
Skills and Requirements
#LI-TI1
Company
PPM TECHNICAL SERVICES, INC
Mobility Information
Please note that any applicant who is not a citizen of the country of the vacancy will be subject to compliance with the applicable immigration requirements to legally work in that country.
At Avangrid we provide fair and equal employment and advancement opportunities for all employees and candidates regardless of race, color, religion, national origin, gender, sexual orientation, age, marital status, disability, protected veteran status or any other status protected by federal, state, or local law.
If you are an individual with a disability or a disabled veteran who is unable to use our online tool to search for or to apply for jobs, you may request a reasonable accommodation by contacting our People and Organization department at careers@avangrid.com.
Avangrid employees may be assigned a system emergency role and in the event of a system emergency, may be required to work outside of their regular schedule/job duties. This is applicable to employees that will work in Connecticut, Maine, Massachusetts, and New York within Avangrid Network and Corporate functions. This does not include those that will work for Avangrid Power.
Avangrid employees may also be assigned a NERC Reliability Standards compliance role supporting Critical Infrastructure Protection (CIP) and/or Operations and Planning (O&P) responsibilities. This is applicable to employees that will work in electric transmission, operations, and cyber security business areas in Connecticut, Maine, Massachusetts, and New York within Avangrid Network and Corporate business areas. NERC Reliability Standards compliance roles and responsibilities may include additional access protections, training, audit engagement, and required evidence retention, and will be communicated by the employee’s management.
Job Posting End Date
January-8-2027